Proton Products Measurement and Control Systems  Proton Products Measurement and Control Systems

HIGH-FREQUENCY SPARK TESTERS


ST Series spark testersRequest a quote


The ST Series includes high frequency and mains frequency spark testers meet the international standards required for cable insulation testing.


High frequency spark testing allows a greatly increased speed capability compared with mains frequency testing, especially in the case of UL1581, where the 9-cycle requirement makes the electrode length required for mains frequency testing impractical. Compared with mains frequency testing, high frequency testing generates an ionization cloud at a relatively low voltage. This ensures complete coverage of the cable surface.

 

The gauge head electronics are housed in a rugged IP65 sealed case that is manufactured from stainless steel, ensuring reliability and long operational life.

 

The ST-IND indicator is a separate unit designed for rack mounting. It includes the ability to remotely set all functions from a device such as a PC or PLC. An optional analogue output is available in the ST-IND.


PRODUCTS:

ST-04-10, ST-IND (indicator unit)

 

[More photos]

PRODUCT SPECIFICATIONS

[DOWNLOAD DATASHEETS]

[View AWG wire size chart]

ST spark tester gauge head  ST0410-12 and ST0410-06
Maximum test voltage 12 kV (ST0410-12)
or 6 kV (ST0410-06)
Max. speed to meet BS5099/UL1581   1000 m/min
Cable diameter range   0.4 ~ 10 mm
Output frequency   3 kHz
Resistive current   4 mA
Capacitive current   15 mA
Remote input voltage for 6 kV   0 ~ 6 V = 0 ~ 6 kV
Remote input voltage for 12 kV   0 ~ 10 V = 0 ~ 12 kV
Electrode length   60 mm
Ambient temperature range   5oC ~ 45oC (41oC ~ 113oF)
Gauge head electronics seal   IP65
Gauge head dimensions   Download dimensional drawing
ST-IND indicator unit  ST-IND
Resolution 0.1 kV
Accuracy   4% +0.01 kV
Voltage   85 ~ 264 VAC rms
Current   2 A rms minimum
Frequency   47 ~ 65 Hz
Power   90 W maximum
Protection   IP50
Ambient temperature range   5oC ~ 45oC (41oC ~ 113oF)
Mounting   19-inch rack; 2U-high panel space
Inputs  

HV enable;

Remote control of HV;

Set HV amplitude;

Auto/Manual fault reset;

Reset fault

Logic inputs  

Spark fault relay;

Bare patch relay

Indicator unit dimensions   Download dimensional drawing

DOWNLOAD DATASHEETS (PDF):

EnglishEnglish
Chinese/ZhongwenZhongwen/Chinese
Back to top

PRODUCT PHOTOS

[Click for larger photos; click on right/left of large image to see previous/next]

ST Series spark tester ST Series spark tester ST Series spark tester ST Series spark tester
ST Series spark tester ST Series spark tester ST Series spark tester ST-IND spark tester indicator unit: control panel
ST Series spark tester ST Series spark tester ST Series spark tester ST-IND spark tester indicator unit: rear panel
Back to top