HIGH-FREQUENCY SPARK TESTERS |
||||
|
The ST Series includes high frequency and mains frequency spark testers meet the international standards required for cable insulation testing. High frequency spark testing allows a greatly increased speed capability compared with mains frequency testing, especially in the case of UL1581, where the 9-cycle requirement makes the electrode length required for mains frequency testing impractical. Compared with mains frequency testing, high frequency testing generates an ionization cloud at a relatively low voltage. This ensures complete coverage of the cable surface.
The gauge head electronics are housed in a rugged IP65 sealed case that is manufactured from stainless steel, ensuring reliability and long operational life.
The ST-IND indicator is a separate unit designed for rack mounting. It includes the ability to remotely set all functions from a device such as a PC or PLC. An optional analogue output is available in the ST-IND.
ST-04-10, ST-IND (indicator unit) |
|
|||
PRODUCT SPECIFICATIONS |
[DOWNLOAD DATASHEETS] |
|||
| ST spark tester gauge head | ST0410-12 and ST0410-06 | |
|---|---|---|
| Maximum test voltage | 12 kV (ST0410-12) or 6 kV (ST0410-06) |
|
| Max. speed to meet BS5099/UL1581 | 1000 m/min | |
| Cable diameter range | 0.4 ~ 10 mm | |
| Output frequency | 3 kHz | |
| Resistive current | 4 mA | |
| Capacitive current | 15 mA | |
| Remote input voltage for 6 kV | 0 ~ 6 V = 0 ~ 6 kV | |
| Remote input voltage for 12 kV | 0 ~ 10 V = 0 ~ 12 kV | |
| Electrode length | 60 mm | |
| Ambient temperature range | 5oC ~ 45oC (41oC ~ 113oF) | |
| Gauge head electronics seal | IP65 | |
| Gauge head dimensions | Download dimensional drawing |
| ST-IND indicator unit | ST-IND | |
|---|---|---|
| Resolution | 0.1 kV | |
| Accuracy | 4% +0.01 kV | |
| Voltage | 85 ~ 264 VAC rms | |
| Current | 2 A rms minimum | |
| Frequency | 47 ~ 65 Hz | |
| Power | 90 W maximum | |
| Protection | IP50 | |
| Ambient temperature range | 5oC ~ 45oC (41oC ~ 113oF) | |
| Mounting | 19-inch rack; 2U-high panel space | |
| Inputs | HV enable; Remote control of HV; Set HV amplitude; Auto/Manual fault reset; Reset fault |
|
| Logic inputs | Spark fault relay; Bare patch relay |
|
| Indicator unit dimensions | Download dimensional drawing |